Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Instrumentation | Pfaudler

Instrumentation | Pfaudler

One reason why our glass-lined reactors are trusted by over 90% of the world's top chemical companies is the sheer reliability of our reaction technologies. These technologies are critical to the safe containment of corrosive contents, maintaining the vessel pressure and ensuring the final batch quality.

Personal Reactor | Reaction Stations | Temperature Probe .

Personal Reactor | Reaction Stations | Temperature Probe .

The Personal Reaction Station has every feature needed for lead development and high throughput applications. The reactor provides precise temperature control, powerful magnetic stirring, and an inert atmosphere for each reaction tube. Reactions are run in 50mL glass tubes that fit inside a heated and cooled reactor base.

Microreactor Technology | Sigma-Aldrich

Microreactor Technology | Sigma-Aldrich

The pressure may deviate, but at room temperature the pressure loss in the glass reactor at a total flow of 10 mL water is 0.7 bar. At a total flow of 20 mL water, the pressure loss increases to about 1.7 bar.

Temperature Probe - an overview | ScienceDirect Topics

Temperature Probe - an overview | ScienceDirect Topics

For example an array of temperature probes is often installed to measure bed temperatures along a fixed bed catalytic reactor or tray temperatures along a distillation column. However, control in many such situations is based upon use of only one or two sensors selected from the complete set, the remaining sensors being used to provide .

Antibodies & Protein Biology - Fisher Scientific

Antibodies & Protein Biology - Fisher Scientific

Ideal for steady state reactions over a large temperature range (1) Ideal for use on small tubes, vessels, or any place where space is limited (1) Liquid-in-glass thermometers (1) Reactor-Ready™ and Reactor-Ready&Trade; Duo Lab Reactors (1) Reactor-Ready™ and Reactor-Ready™ Duo Lab Reactors (2)

XELSIUS High Speed Solubility & Synthesis Reactor .

XELSIUS High Speed Solubility & Synthesis Reactor .

XELSIUS solubility & synthesis reactor, is capable of taking charge of precise and individual temperature controll, stirring and turbidity measurements. The right fit in a wide range of applications up to fully automated chemical processing. XELSIUS offers 10 individual reactor .

New method measures temperature within 3D objects .

New method measures temperature within 3D objects .

Engineers have made it possible to remotely determine the temperature beneath the surface of certain materials using a new technique they call depth thermography. The method may be useful in applications where traditional temperature probes won't work, like monitoring semiconductor performance or next-generation nuclear reactors.

Temperature measurements with two different IR sensors in .

Temperature measurements with two different IR sensors in .

Measuring the internal temperature of the reactor. We opted for a fiber optic probe (Neoptix T1 Fiber Optic Temperature Probe, Neoptix Inc., Québec City) to be able to measure the temperature inside the glass reactor. The probe was positioned slightly above the measurement zone of the IR sensor (see Fig. 2, exemplified with IR sensor 1) to .

Reactor instrumentation: New breakthroughs in high .

Reactor instrumentation: New breakthroughs in high .

Apr 08, 2019 · Because of its patented molybdenum-niobium construction, the HTIR-TC is the only high-temperature (>1,250° C) probe that can withstand the environments inside reactors and nuclear fuel rod assemblies for sustained periods of time.

New method measures temperature within 3D objects .

New method measures temperature within 3D objects .

The method may be useful in applications where traditional temperature probes won't work, like monitoring semiconductor performance or next-generation nuclear reactors.

Degradation of RPV steel structure after 45 years of .

Degradation of RPV steel structure after 45 years of .

Jul 06, 2020 · This paper presents the results of the complex structural studies of RPV steels (weld and base metal from both beltline and nozzle regions) from the d.

Factory Price CBD Distillate Crystallization Glass Reactor .

Factory Price CBD Distillate Crystallization Glass Reactor .

Factory Price CBD Distillate Crystallization Glass Reactor 50L, US 500 - 5000 / Set, New, Semi-Automatic, Reaction Kettle.Source from Shanghai Yuhua Instrument Equipment Co., Ltd. on .

Lab Reactors - Scientific Solutions

Lab Reactors - Scientific Solutions

- Reactor vessel openings (units/standard): 4/NS29/32, 1/ NS14/23 - Reactor vessel openings (units/standard): 4/NS29/32, 1/ NS14/23 rodavis - Material in contact with medium: borosilicate glass 3.3, PTFE - Working temperature max °C: 200 - Working temperature min. °C: room temperature - Temperature probe Ø6 [mm]: PTFE-encapsulated stainless .

Normal Operation - Reactor Control

Normal Operation - Reactor Control

The reactor control system would sense this decrease in steam pressure and withdraw control rods to increase the reactor coolant temperature. This type of reactor control produces ideal steam conditions at the main turbine inlet for all loads from initial load (e.g. 30%) to load.

Temperature Sensor Installation for Best Response and Accuracy

Temperature Sensor Installation for Best Response and Accuracy

The process temperature will vary with process fluid location in a vessel or pipe due to imperfect mixing and wall effects. For highly viscous fluids such as polymers and melts flowing in pipes and extruders, the fluid temperature near the wall can be significantly different .

China Lab Use Double Layer Glass Reactor Small Glass Lined .

China Lab Use Double Layer Glass Reactor Small Glass Lined .

China Lab Use Double Layer Glass Reactor Small Glass Lined Reactor with Ce, Find details about China Glass Reactor, Double Layer Glass Reactor from Lab Use Double Layer Glass Reactor Small Glass Lined Reactor with Ce - Zhengzhou Nanbei Instrument Equipment Co., Ltd

Calcium Probe - Bulk Reef Supply

Calcium Probe - Bulk Reef Supply

The countersunk holes accept almost all major brands of probes, even Neptune's temperature probe. Dosing Tube Holder The RM30 sump comes standard with four push-connect adapters that can accept any 1/4" OD tubing. They are great for connecting dosing pumps, ATO, and calcium reactor.

Temperature Probe | os4200

Temperature Probe | os4200

The os4200s are three versions of a stainless steel temperature probe based on fiber Bragg grating (FBG) technology. The os4200 Temperature Probes are sealed, stainless steel tubes that are designed to make handling easy and sensor installation fast and repeatable. It is

Microwave Temperature Probe – BestMicrowave

Microwave Temperature Probe – BestMicrowave

Jun 29, 2016 · Meat probe sensor kitchenaid ovens electric oven customized 200k oem odm cwf h6 d customized 200k oem odm cwf h6 d gl beaker reactor containing the china waterproof metal probe.Thermometrics Sensor Emblies Meat ProbeHave 2 Microwave Oven Temperature Meat Thermometer Probe Cable LibGe Microwave Oven Meat Temperature Probe Wb20t10025 .

Plasma-assisted methane combustion in swirled-flow .

Plasma-assisted methane combustion in swirled-flow .

The degree of plasma non-equilibrium can be determined via probe measurements and spectroscopic emission measurements. In addition, the acoustic modes resulting from combustion processes within the enclosure can be evaluated using a high-temperature probe-type microphone.

Thermocouples - Parr Instrument Company

Thermocouples - Parr Instrument Company

Parr offers a variety of thermocouples for use in our reactors and pressure vessels. The standard thermocouple is a Type J (iron-constantan) which is compatible with the operating temperature range of these vessels. The thermocouples are furnished with a sealed 1/8″ OD stainless steel sheath and include a standard plug connection at the end of the [.]

Ultrasonic Extractor Reactor - Ultrasonic FLOW CELL .

Ultrasonic Extractor Reactor - Ultrasonic FLOW CELL .

Solid .Autoclavable.Chamber housing S.S 316, Volume of liquid 500ml.Temperature Probe Allows sample temperature to bemonitored up to 100 DegreeC. The propagation of ultrasonic waves is based on the medium. There is an alternating period of positive and negative pressure during the propagation of ultrasonic waves in the medium.

Nano-Reactor - DENSsolutions

Nano-Reactor - DENSsolutions

The Nano-Reactor's micro-heater is based on the proven and well established DENSsolutions MEMS technology that offers superior performance in temperature accuracy, reliability and stability. The micro-heater is encapsulated in inert SiNx to ensure that the metal .

Industrial reactor - hydrogenator reactor

Industrial reactor - hydrogenator reactor

It is used to heat, cool & control reactor temperature by circulating thermic fluid in theautoclave jacket. It consists of a bath, pump, heater, compressor, condenser & level switch. Temperature range: -35°C to 200°C / -80°C to 180°C. Suitable for reactors up to 1000 ltr volume.

Resistance thermometer - Wikipedia

Resistance thermometer - Wikipedia

Resistance/temperature relationship of metals. Common RTD sensing elements constructed of platinum, copper or nickel have a repeatable resistance versus temperature relationship (R vs T) and operating temperature range.The R vs T relationship is defined as the amount of resistance change of the sensor per degree of temperature change. The relative change in resistance (temperature coefficient .

Temperature probes - Rolls-Royce

Temperature probes - Rolls-Royce

Normal Operation - Reactor Control

Reactor pressure vessel - Wikipedia

Reactor pressure vessel - Wikipedia

The reactor vessel used in the first US commercial nuclear power plant, . the gas cooled fast breeder reactor, and the high temperature gas cooled reactor. An example of a gas cooled reactor is the British Magnox. Pressurized heavy-water reactor . The coolant level measurement probe also enters the vessel through the reactor vessel head. .

Temperature Sensor Installation for Best Response and Accuracy

Temperature Sensor Installation for Best Response and Accuracy

The process temperature will vary with process fluid location in a vessel or pipe due to imperfect mixing and wall effects. For highly viscous fluids such as polymers and melts flowing in pipes and extruders, the fluid temperature near the wall can be significantly different .

Fiber-Optic Multipoint Sensor System with Low Drift for .

Fiber-Optic Multipoint Sensor System with Low Drift for .

To gain access for temperature measurement, selected reactor tubes are axially equipped with protective tubes that demarcate the temperature probe from the reaction volume. The outer diameters of the protective tubes have to be as small as possible to ensure representative conditions when compared to unequipped reactor tubes.

US20140123896A1 - Probe assembly for a fluid bed reactor .

US20140123896A1 - Probe assembly for a fluid bed reactor .

Embodiments of a probe assembly for a fluid bed reactor are disclosed. The probe assembly includes a fluid bed reactor (FBR) member, and a pressure tap comprising a wall defining a passageway within which the FBR member is located. Exemplary FBR members include, but are not limited to, a thermocouple, a seed pipe, a particle sampling line, a gas sampling line, a gas feed line, a heater, a .